2. Your data: images, folders and the parameter file¶
Time: 10 minutes. You need: the repository folder from page 1.
What this step does¶
Before you compute anything, you must know what the program expects: which files, in which folders, with which names, and where the settings are. Most beginner problems are a file in the wrong place, or a setting that does not match the images.
The example¶
test_data/test_cavity_small is a real experiment, cut down to 5 frames of 256 x 256 pixels:
test_cavity_small/
├── parameters_Run1.yaml all settings of this experiment, in one file
├── img/ the images: one file per camera and frame
│ ├── cam1.10000 cam1.10001 ... cam1.10004
│ └── cam2.10000 ... cam3.10000 ... cam4.10000 ...
├── cal/ the calibration: two small text files per camera
│ ├── cam1.tif.ori where camera 1 is and where it looks (page 3)
│ ├── cam1.tif.addpar its lens distortion
│ └── ... cameras 2, 3, 4
└── res/ the results are written here
The example folder has a few more things: ground_truth/ (the true particle positions, because the example is synthetic) and
parameters/ (an older format of the settings). You can ignore them. If your copy already has a res/run.zarr from an
earlier run, delete res/ first, so that every result you see is made by your own run.
- Image names are
cam<camera number>.<frame number>. The frame number is a counter. Here it runs from 10000 to 10004. - One frame is one moment in time, seen by all four cameras:
cam1.10000,cam2.10000,cam3.10000,cam4.10000.

One moment, seen from four sides. The bright dots are tracer particles. The four pictures differ because each camera looks from another side.
Work on a copy¶
The program writes its results into the folder. Do not write into the original. Make a copy and work in the copy for the whole course:
(On Windows, copy the folder in the file explorer and name it my_run.)
The parameter file¶
my_run/parameters_Run1.yaml holds all settings. You rarely edit it by hand, because the window does it for you. But you must
be able to read it. These are the parts that matter first:
| Section | Key | Example | Meaning |
|---|---|---|---|
| (top) | num_cams |
4 | number of cameras |
ptv |
imx, imy |
256, 256 | image size in pixels |
ptv |
pix_x, pix_y |
0.012 | size of one sensor pixel in mm (12 micrometres) |
ptv |
mmp_n1, mmp_n2, mmp_n3, mmp_d |
1.0, 1.46, 1.33, 6.0 | refractive index of air, glass and water, and the glass thickness in mm (page 3) |
cal_ori |
img_ori |
cal/cam1.tif.ori ... |
which calibration file belongs to which camera |
sequence |
first, last |
10000, 10004 | the frames to process |
criteria |
X_lay, Zmin_lay, Zmax_lay |
-10..10, -20..25 | the box in mm where you expect particles (the measurement volume) |
criteria |
eps0 |
0.06 | how far (mm on the sensor) a spot may be from its epipolar line and still match (page 5) |
track |
dvxmax and similar |
15.5 | the largest step a particle may make between two frames, in mm (page 6) |
The image size, the pixel size and the volume are the settings that most often do not fit a user's own images.
Do it¶
Check that the program finds all files:
What you should see¶
The program prints one line Loaded calibration for camera N from ... for each camera, and then this line:
Check that it worked¶
The number of cameras and the image size must be the same as in your own images. If they are wrong, nothing later will be right.
If it did not work¶
| You see | Cause | What to do |
|---|---|---|
FileNotFoundError with a .ori name |
the path in cal_ori is relative to the folder you started in |
run from the repository folder, or use full paths |
| the camera tabs are empty | the image names do not follow cam<N>.<frame> |
rename the images, or set base_name in the sequence section |
cameras: shows a wrong number |
num_cams and the number of img_ori entries differ |
make them equal |
Next: 3. Cameras and calibration →{ .md-button .md-button--primary }
